亚洲一区二区三区蜜桃av-色就是色欧美日韩在线观看-中文字幕精品久久一二三区红杏-无码免费婬AV片在线观看

Home    硬件系統    Manual Ultrafiltration System
圖-圖片2

Manual Ultrafiltration System

Data Download:

Alioth Manual Ultrafiltration System, with its modular design and?flexible combination options, supports the use of filters or hollow fibers?of different areas, thus realizing various filtration requirements ranging?from a minimum of 0.1 m2 to a maximum of 20 m2, or even a larger area.?It is operated manually, providing convenient control. Both desktopand?ground-based versions are available to meet different site needs.?The overall system design is compact and space-saving.
Depth Stacked DataSheet
  • 我是段落。點擊這兒添加你的文字并編輯它,非常容易。-雙擊進行編輯

     

    • Compatible with different types of consumables, and flat filters or hollow fibers of different areas.

    • Compatible with mainstream brands of filters and hollow fibers in the market.

    • Sanitary design, with main liquid-contacting materials being 316 L stainless steel and FDA-compliant non-metal materials such as.

    • EPDM / PTFE/TPE commonly used in pharmaceutical industry.

    • Resistant to acid and alkali corrosion, liquid-contacting surfaces can be selected with Ra < 0.4 μm EP or Ra < 0.6 μm MP as needed.

    • The holder adopts standard TC connector, allowing free adaptation to the system.

    • Compact and rational system design, resulting in a small footprint.

    • Simple system configuration and convenient operation.

    • Can adapt to a filtration area of approximately 0.1-20 m2.

    • Pump overpressure protection, mechanical interlocking, safe and reliable operation.

    • Reliable quality, traceable process, accessible liquid-contacting material certificate and cleanliness certificate.

    • High-quality service, and accessible FAT / SAT / IQ / OQ service packages that can be purchased according to needs.

     

  •  

    • Vaccine purification

    • Virus purification

    • Blood product purification

    • Monoclonal antibody purification

    • Recombinant protein purification

    • Endotoxin removal

     

  • Product Specifications

    Membrane area Common filter
    series: 0.1-0.5 m2
    Common filter
    series: 0.5-2.5 m2
    Common filter series:
    5-10 m2
    Common filter series:
    10-20 m2
    Pump Optional diaphragm pump or peristaltic pump
    Operation mode Manual control of TMP, manual control of valves, manual recording of data
    Power supply 220V / 50Hz ( P + N + PE ) or 380 V / 50 Hz (3 P + N + PE)
    System pressure resistance Maximum 6 bar
    Operating temperature SS 316 L; Polymer; EPDM; Silicone; TPE
    Pipeline material 4 - 40°C recommended for plastic material part; 4 - 60°C recommended for SS 316 L part
    Sanitary connection method Sanitary chuck
    Liquid-contacting surface
    finish
    Optional: Ra < 0.4 μm EP or Ra < 0.6 μm MP

    ※For ultrafiltration system with a larger area or other customization requirements, please contact local sales and technical personnel

     

    PID Flowchart